Beverage Carbonation - TCM Series

 

easyCARB TCM Series

TCM Series

 

  • Highest flow rates

  • Stainless steel hard fittings and plumbing lines

  • Isolation valves for easy service 

  • Heavy-duty, low temperature final line regulator

  • Fill line relief valve

  • Full-view, non-binding contents gauge

  • Efficient venturi fill system

  • Optional corrosion resistant coatings available for water treatment applications

  • Highest corrosion resistant coatings available

  • Lowest NER

  • Higher capacity equals fewer fills

  • Separate liquid withdrawal port 

  • Most cost efficient system for high flow

  • Protective shroud

  • On board electronic pressure building system

 

EC Series Specifications
TCM-600-120V TCM-600-240V
Part Number EC60-0C01 EC60-0C02
Dimensions  

Diameter in. (mm)

22   (559) 22   (559)

Height in.  (mm)

70.4  (1788) 70.4   (1788)

Weight, Empty lb  (kg)

360   (163) 360   (163)
Capacity COSaturated                @ 125 psig (8.6 bar)  

Liquid lb.  (kg)

594   (269) 594   (269)

Gaseous cu.ft. (cu. m) @NTP (STP)

5195   (136) 5195   (136)
Flow Rates  

Peak Demand ob./hr. (kg/hr)

30.0   (13.6) 60.0   (27.2)*

Continuous lb./hr. (kg. hr)

20.0   (9.1) 40.0   (18.1)
Minimum Usage (No venting)  

Liquid lb./day 9kg/day)

2.9   (1.32) 2.9   (1.32)

Pressure Building System

 

Standard Operating Pressure

125 psig (8.6 bar) 125 psig (8.6 bar)
Safety Device Settings  

Inner Container Primary Relief Valve

300 psig (31.0) 300 psig (31.0)

Inner Container Safety Head

450 psig (31.0) 450 psig (31.0)
Electrical Requirements  
Heater Voltage 120 VAC 208/240 VAC
Heater Current 7.5 amps 6.5/7.5 amps